products
SG125CX-P2 125KW Solar String Inverter
SG125CX-P2 125KW Solar String Inverter

SG125CX-P2 125KW Solar String Inverter

125KW Solar inverter with 12×98.5% MPPTs, 500W+ PV compatibility, smart IV diagnostics, 240mm² Al cable support, IP66/C5/SPD protection, and AFCI 2.0 safety.

CATEGORY:
Description

HIGH PERFORMANCE

12 independent MPPT channels achieving 98.5% peak efficiency.

15A DC input capacity for seamless integration with 500W+ solar panels.

Adaptive shading mitigation technology.

INTELLIGENT OPERATION

Real-time component health monitoring & safeguarding.

IV curve scanning for precise fault detection.

Grid event logging for streamlined remote maintenance.

COST-EFFICIENT DESIGN

Supports aluminum AC cabling up to 240mm².

Pre-installation-ready AC connections via modular cable trays.

ROBUST PROTECTION

IP66-rated weatherproof & corrosion-resistant construction.

Dual-stage DC surge protection (Type I+II) + AC Type II SPD.

Advanced arc fault detection (AFCI 2.0 compliance).


Type DesignationSG125CX-P2

Input ( DC )

  • Recommended max. PV input power175 kWp
  • Max. PV input voltage1100 V
  • Min. PV input voltage / Startup input voltage180 V / 200 V
  • Nominal PV input voltage600 V
  • MPPT voltage range180 V – 1000 V
  • No. of independent MPP inputs12
  • No. of PV strings per MPPT2
  • Max. PV input current360 A ( 30 A * 12 )
  • Max. DC short-circuit current480 A ( 40 A * 12 )
  • Max. current for DC connector30 A

Output ( AC )

  • Rated AC output power125 kW
  • Max. AC output apparent power125 kVA
  • Max. AC output current181.1 A
  • Rated AC output current( at 230V )181.1 A
  • Rated AC voltage3 / N / PE, 220 V / 380 V, 230 V / 400 V
  • AC voltage range320 V – 480 V
  • Rated grid frequency / Grid frequency range50 Hz / 45 – 55 Hz, 60 Hz / 55 – 65 Hz
  • Harmonic ( THD )< 3 % ( at rated power )
  • Power factor at nominal power / Adjustable power factor> 0.99 / 0.8 leading – 0.8 lagging
  • Feed-in phases / AC connection3 / 3-N-PE
  • Max. efficiency / European efficiency98.5% / 98.3%

Protection and Function

  • Grid monitoringYes
  • DC reverse polarity protectionYes
  • AC short-circuit protectionYes
  • Leakage current protectionYes
  • Ground fault monitoringYes
  • Surge protectionDC Type I + II / AC Type II
  • DC switchYes
  • PV string current monitoringYes
  • Arc fault circuit interrupter (AFCI)Yes
  • PID recovery functionYes
  • Optimizer compatibilityOptional
  • RSD compatibilityOptional

General Data

  • Dimensions ( W * H * D )1020 mm * 795 mm * 360 mm
  • Weight≤ 93 kg
  • Mounting methodWall-mounting bracket
  • TopologyTransformerless
  • Degree of protectionIP66
  • Night power consumption< 5 W
  • CorrosionC5
  • Operating ambient temperature range-30 to 60 ℃
  • Allowable relative humidity range (non-condensing)0 % - 100 %
  • Cooling methodSmart forced air cooling
  • Max. operating altitude4000 m
  • DisplayLED, Bluetooth+APP
  • CommunicationRS485 / WLAN ( optional ) / Ethernet ( optional )
  • DC connection typeEVO2 ( Max. 6 mm² )
  • AC connection typeOT / DT terminal ( Max. 240 mm² )
  • AC cable specificationOutside diameter 30 mm - 60 mm
  • ComplianceIEC 62109-1, EN/IEC 61000-6-1/2/3/4, IEC 61727, IEC 62116, EN 50549-1/2, UTE C15-712-1, VDE V 0126-1-1, VDE-AR-N 4105:2018, VFR 2019, NC RfG, G99, UNE 217002, NTS, CEI 0-21 2019,CEI0-16 2019, NRS-097-2-1, IEC 63027
  • Grid SupportQ at night function, LVRT, HVRT, active & reactive power control and power ramp rate controlramp rate control